Structure UtcParameters

┗ HPE.Gnss.UtcParameters

namespace: HPE.Gnss
packed: true

Description

Conversion data between GPS time and UTC.

Summary

Fields defined in HPE.Gnss.UtcParameters

a0, a1, DeltaTls, tot, WNt, WNlsf, DN, DeltaTlsf

Field Detail

a0 (required) : int32, in 2^-30 seconds

Constant term of the polynomial in seconds. Value is integer encoded with scale factor 2^-30.

a1 (required) : int24, in 2^-50 seconds

First order term of the polynomial in seconds/second. Value is integer encoded with scale factor 2^-50.

DeltaTls (required) : int8, in seconds

Delta time due to Leap Seconds.

tot (required) : uint8, in 2^12 seconds

Time of Utc Data. Value is integer encoded with scale factor 2^12

WNt (required) : uint8, in weeks

UTC Reference Week Number in weeks

WNlsf (required) : uint8, in weeks

Week Number LeapSecond Future in weeks

DN (required) : uint8, in days

Day number in days

DeltaTlsf (required) : int8, in seconds

Delta time due to Leap Seconds Future